I read in !emc-pstc that John Woodgate <j...@jmwa.demon.co.uk> wrote (in
<flrep9a0m3d8e...@jmwa.demon.co.uk>) about 'GTEM for full compliance
testing?', on Thu, 6 Dec 2001:
>I read in !emc-pstc that Gelfand, David <david.gelf...@ca.kontron.com>
>wrote (in <DAE684A26044B6469EF0A1E1565116820F0AFC@semsl131>) about 'GTEM
>for full compliance testing?', on Thu, 6 Dec 2001:
>>I imagine this has probably been discussed at length before.  Can full
>>compliance, emissions to FCC Part 15/ 55022  and rf radiated immunity to
>>55024/61000-4-3 be tested in a GTEM cell?  
>
>Not to 55024/61000-4-3. A new section, 61000-4-20, will be published
>next year and ***when/if it is called up in product standards such as
>55024*** it will be possible to use GTEM cells for full compliance.

The CDV is now issued, as a CISPR/A document.
-- 
Regards, John Woodgate, OOO - Own Opinions Only. http://www.jmwa.demon.co.uk 
After swimming across the Hellespont, I felt like a Hero. 

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        pstc_ad...@garretson.org
     Dave Heald                davehe...@mediaone.net

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old 
messages are imported into the new server.

Reply via email to