Bill,

Thanks for your advice.  I believe it is a new requirement and afraid no
accredited labs doing this test.  It sounds the big labs should be equipped
with the necessary facilities since the standard becomes in force already.

Thanks to all replies!

Regards,

Scott


On 22/11/2011 12:34 AM, "Bill Stumpf" <bstu...@dlsemc.com> wrote:

> Scott,
> Testing to 6GHz became mandatory on October 1, 2011.  You can comply with
> EN55022:2006 / A1:2007, or EN55022:2010.  Testing above 1GHz is conditional
> based on the clock /timing signals of the device being tested.
> 
> I would hope that labs are equipped and educated to test above 1GHz since it
> has been an FCC requirement for years.  Test sites (OATS of chambers) must
> also meet CISPR 16 requirements for Site VSWR above 1GHz.
> 
> Bill
> 
> 
> 
> Bill Stumpf
> D.L.S. Electronic Systems, Inc.
> 166 South Carter Street
> Genoa City WI 53128
> Ph: 262-279-0210
> Email: bstu...@dlsemc.com
> 
> 
> 
> -----Original Message-----
> From: Scott Xe [mailto:scott...@gmail.com]
> Sent: Saturday, November 19, 2011 10:30 PM
> To: EMC-PSTC@LISTSERV.IEEE.ORG
> Subject: [PSES] EN 55022 for iTE
> 
> Dear All,
> 
> I have learnt that the latest version requires to test the products upto 6
> GHz from 1 GHz.  When will it commence on which amendment? Have most of
> public labs well equipped to conduct the test to the new requirements?
> 
> Thanks and regards,
> 
> Scott 
> 
> -
> ----------------------------------------------------------------
> This message is from the IEEE Product Safety Engineering Society emc-pstc
> discussion list. To post a message to the list, send your e-mail to
> <emc-p...@ieee.org>
> 
> All emc-pstc postings are archived and searchable on the web at:
> http://product-compliance.oc.ieee.org/
> Graphics (in well-used formats), large files, etc. can be posted to that URL.
> 
> Website:  http://www.ieee-pses.org/
> Instructions:  http://listserv.ieee.org/request/user-guide.html
> List rules: http://www.ieee-pses.org/listrules.html
> 
> For help, send mail to the list administrators:
> Scott Douglas <emcp...@radiusnorth.net>
> Mike Cantwell <mcantw...@ieee.org>
> 
> For policy questions, send mail to:
> Jim Bacher:  <j.bac...@ieee.org>
> David Heald: <dhe...@gmail.com>

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at:
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <emcp...@radiusnorth.net>
Mike Cantwell <mcantw...@ieee.org>

For policy questions, send mail to:
Jim Bacher:  <j.bac...@ieee.org>
David Heald: <dhe...@gmail.com>

Reply via email to