No From: [email protected] [mailto:[email protected]] On Behalf Of Boštjan Glavic Sent: Monday, August 05, 2013 9:46 PM To: [email protected] Subject: breakage of the fuse
Dear safety experts, During the abnormal tests in primary circuit, internal input fuse operates and glass breaks. However, fuse is inside the tubing and broken glass does not spread around. Would you accept such construction? Best regards, Bostjan SIQ - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>