Hi Greg:

 

 

The standard is incorrect in requiring tests of both polarity d.c.  There is no 
physical rationale for both polarities.  But, at this time, if you opt for d.c. 
testing, you must test with both polarities.  I would advise testing with a.c. 
to avoid capital expense of a new d.c. tester.  

 

 

Best regards,

Rich

 

 


-
----------------------------------------------------------------