[EMAIL PROTECTED] wrote: > > One thing I see in the ini is that it appears to be a bit out of date with > the current head of trunk. One thing that changed recently is a switch from numerical units in the task section to names. > > LINEAR_UNITS = mm > ANGULAR_UNITS = degree > > I'd encourage you to pick up the stepper mm ini file from the release you are > using and edit in your changes. We have made several modifications like this > in recent months that prevent migrating older ini files forward. > > Rayh
I agree that its a good idea to stay up-to-date, but this particular issue is not the cause of the problem. The older numerical units values still work fine. Regards, John Kasunich ------------------------------------------------------------------------- Take Surveys. Earn Cash. Influence the Future of IT Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys-and earn cash http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users