Gentlemen, Upon further investigation I am unable to use the lead screw compensation files we collected. I adjusted the scale to minimize the compensation magnitude. This allowed me to machine the test article to a 'pretty close' configuration. I have since discovered the lead screw comp is not applied.
I have: 1: the latest trunk - cvs and compile yesterday 2: 6.06 3: COMP_FILE = joint0.cmp - in the [AXIS_0] section of my .ini file 4: joint0.cmp - in the same directory as the .ini file - using triplets of 0.0 0.006 0.0 etc questions - comments - HELP :) thanks Stuart ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users