Gentlemen,
  Upon further investigation I am unable to use the lead screw
compensation files we collected.
   I adjusted the scale to minimize the compensation magnitude. This
allowed me to machine the test article to a 'pretty close'
configuration. I have since discovered the lead screw comp is not
applied.

I have:
   1: the latest trunk - cvs and compile yesterday
   2: 6.06
   3: COMP_FILE = joint0.cmp     -  in the [AXIS_0] section of my .ini file
   4: joint0.cmp  -  in the same directory as the .ini file - using
triplets of   0.0    0.006  0.0 etc

questions - comments - HELP :)
thanks
Stuart

-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to