On Wed, Nov 12, 2008 at 05:43:19AM +0100, Maximilian wrote: > When i close the axis gui with the big X in the upper right corner of > the window my amps stay tuned on and start drifting because there is no > pid controller providing any commanded position. > [...] > Hardware is a stg2 card.
Does the STG have a watchdog? If not, you really need an external charge pump in your estop chain. There's no other safe way. Successfully exiting the software could do something graceful to the STG, but that's not the only way the software might "go away" while the DACS are on full. ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users