>> it powers on in the same phase as it powered off, it might pull in to a
>> spot +-4 full steps from where it was powered off.
>
> No, not 'MIGHT'... it WILL. Been there, tried that... Not even servo
> drives like that.
>
> The best solution is to use drives which limit the idle current if
> that is necessary. Gecko's can do that.
> On the other hand... a 'warm' stepper shows proper use. Don't humanize
> steppers 8).
> Rainer
>
>
Both RTA(Pavia) and Compumotor S-6 packaged stepper drives have provision
to reduce motor current after only a few seconds of inactivity.  The
degree of reduction (Holding torque) is settable to various values %.

Not so much information to your question,  but a hardware solution to the
need.

Cal Grandy


------------------------------------------------------------------------------