On Wed, 04 Nov 2009 09:12 +0100, "Sven Wesley" <svenne.d...@gmail.com>
wrote:
> 2009/11/4 许军 <sed...@163.com>
> 
> > emc2 always appear "joint 0 following error"
> >
> >
> >
> You set the speed on the first G0-line: G0 Z50 F3000 (Goto Z 50 with the
> Feed of 3000 units/min). Then the speed will be remembered for the rest
> of the G0-lines.

G0 is a rapid traverse move and always goes at the speed determined by
the ini file limits.  It is NOT affected by an F value in the g-code.
The F only sets the feed rate for G1, G2, G3, and other cutting moves.

John Kasunich


-- 
  John Kasunich
  jmkasun...@fastmail.fm


------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 
trial. Simplify your report design, integration and deployment - and focus on 
what you do best, core application coding. Discover what's new with
Crystal Reports now.  http://p.sf.net/sfu/bobj-july
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to