On Wed, 04 Nov 2009 09:12 +0100, "Sven Wesley" <svenne.d...@gmail.com> wrote: > 2009/11/4 许军 <sed...@163.com> > > > emc2 always appear "joint 0 following error" > > > > > > > You set the speed on the first G0-line: G0 Z50 F3000 (Goto Z 50 with the > Feed of 3000 units/min). Then the speed will be remembered for the rest > of the G0-lines.
G0 is a rapid traverse move and always goes at the speed determined by the ini file limits. It is NOT affected by an F value in the g-code. The F only sets the feed rate for G1, G2, G3, and other cutting moves. John Kasunich -- John Kasunich jmkasun...@fastmail.fm ------------------------------------------------------------------------------ Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day trial. Simplify your report design, integration and deployment - and focus on what you do best, core application coding. Discover what's new with Crystal Reports now. http://p.sf.net/sfu/bobj-july _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users