Am 04.02.2012 08:25, schrieb gene heskett:
> I have moved these labels one at a time to other layers so I can try 5 
> layers per run of pbc-gcode, but I'm having zero luck finding the magic 
> tname label that works.
> 
> So, what layer in eagle do I move these text labels to so they come out in 
> the $basename.top.txt.ngc file?  
> 
> And is there something else I need to do, the pcb-gcode previewer shows 
> total blanks where they should be at all times.

To show the text in the top ngc file you have to put it into the top
layer. This way it will get milled in the same step as the top traces
and will be shown in the preview window of pcb-gcode. The TNAME layer is
only for reference and will never be in the generated gcode.

Ciao,
     Rainer

------------------------------------------------------------------------------