On Mon, 21 Jan 2013, John Stewart wrote:

> Date: Mon, 21 Jan 2013 20:53:16 -0500
> From: John Stewart <alex.stew...@crc.ca>
> Reply-To: "Enhanced Machine Controller (EMC)"
>     <emc-users@lists.sourceforge.net>
> To: "Enhanced Machine Controller (EMC)" <emc-users@lists.sourceforge.net>
> Subject: [Emc-users] 5i25 and pncconf and g540
> 
> Can anyone tell me why it is so difficult to configure a G540 to run with a 
> 5i25?

Sure, its difficult with pncconf because there are no G540 xml files available 
for pncconf yet so pncconf will not make a usable set of configuration files.

If you want to use a G540 with a 5I25 you are currently better off
starting with the example hm2-stepper example hal/ini files, and making the 
changes and additions you need for the 5I25 (changes to support 5i25 are 
minor)

The example are very basic so limits/homing/probe inputs etc must be added


Peter Wallace