What do you mean by "cycle", "sequence" and "comp"?
As I wrote earlier - when axis.n.index-enable is disconnected, and bldc.init takes place, motor start to spin, index-enable goes high, motor encoder reaches the index and then it goes low like it should be. But when axis.n.index-enable is connected, the motor even does not start to rotate and index-enable signal goes low immediately! On 04/30/2014 02:34 PM, Marius Liebenberg wrote: > Are you saying that it goes high during the cycle somewhere and then low > again after every sequence or Low - high-low after the sequence. You may > have to do a comp to time that out or ignore it if some other conditions > are still met. ------------------------------------------------------------------------------ "Accelerate Dev Cycles with Automated Cross-Browser Testing - For FREE Instantly run your Selenium tests across 300+ browser/OS combos. Get unparalleled scalability from the best Selenium testing platform available. Simple to use. Nothing to install. Get started now for free." http://p.sf.net/sfu/SauceLabs _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users