I've seen Phoenix connectors fail similarly on step motor drives. But they 
usually went noticeably intermittent long before they looked quite that bad.



Sent from my Verizon 4G LTE smartphone


-------- Original message --------
From: John Dammeyer <jo...@autoartisans.com>
Date: 4/6/20 12:25 AM (GMT-05:00)
To: "'Enhanced Machine Controller (EMC)'" <emc-users@lists.sourceforge.net>
Subject: [Emc-users] Gecko Failure

[EXTERNAL EMAIL] Be sure links are safe.

Anyone ever run into this sort of thing with a G213V driver?
http://www.autoartisans.com/mill/G213V-Failure.jpg

It was running the Knee with a 1200 oz-in motor and 60VDC power supply.

John