Hello,
I probably misunderstood something, but I take these inputs from the Beckhoff
EL2522 XML file:
<OpMode>
<Name>DC</Name>
<Desc>DC-Synchron</Desc>
<AssignActivate>#x700</AssignActivate>
<CycleTimeSync0 Factor="1">0</CycleTimeSync0>
<ShiftTimeSync0 Input="0">0</ShiftTimeSync0>
<CycleTimeSync1 Factor="1">0</CycleTimeSync1>
<ShiftTimeSync1>140000</ShiftTimeSync1>
</OpMode>
So I assumed that the sync1 shift time should be configured somewhere.
Philippe Leuba
> On 13 Mar 2017, at 00:01, Gavin Lambert <[email protected]> wrote:
>
> According to the documentation that I can find for the EL2522, it only uses
> SYNC0, so I'm not sure what you're referring to here. (Granted I only
> glanced through so I might have missed something.)
_______________________________________________
etherlab-users mailing list
[email protected]