Can one regulator monitor multiple cells in parallel?  That is if you have four 
strings of twenty lets say would you need 20 or 80 units?  Lawrence Rhodes...



>________________________________
> From: David Rees <dree...@gmail.com>
>To: Lawrence Rhodes <primobass...@sbcglobal.net>; Electric Vehicle Discussion 
>List <ev@lists.evdl.org> 
>Sent: Thursday, April 3, 2014 11:55 AM
>Subject: Re: [EVDL] BMS for leaf cells
> 
>
>On Thu, Apr 3, 2014 at 10:37 AM, Lawrence Rhodes
>
><primobass...@sbcglobal.net> wrote:
>> I got a deal for a Leaf pack for 2500 dollars.  However I've gotten an 
>> estimate for
>> thousands for the BMS.  Is there a reliable BMS I don't have to spend 
>> thousands
>> on?  Will be dividing up the pack into strings of parallel and series to  
>> make 156vdc
>> after charging.
>
>MiniBMS would be an option if it supported different voltage cutoffs
>(does it? I don't know). But even then you need 48 cell-modules if you
>split the pack in half which is going to cost you about $700.
>
>-Dave
>
>
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://lists.evdl.org/private.cgi/ev-evdl.org/attachments/20140403/305124ad/attachment.htm>
_______________________________________________
UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub
http://lists.evdl.org/listinfo.cgi/ev-evdl.org
For EV drag racing discussion, please use NEDRA 
(http://groups.yahoo.com/group/NEDRA)

Reply via email to