Hi John,

Here's my post on this subject

http://www.corbinstreehouse.com/blog/2011/01/plug-bug-battery-bus-bars/

I am using 1/8" by 1" copper bar stock. Works fine to pull 500+amps through it. 
I regularly pull 300amps through it with no problem and no heat buildup. 

corbin

On May 4, 2014, at 2:14 PM, John Lussmyer <cou...@casadelgato.com> wrote:

> So, I'm updating my F250 to use Nissan Leaf modules.  
> 3 modules in parallel, 40 sets in series.
> Trying to figure out bus bar size I'll need.
> Truck cruises at 60mph, at about 125A.  The 2 mile steep hill from the ferry 
> will probably be more like 400A (possibly more.)
> Would 3/16"x3/4" be big enough?
> 
> --
> Tigers prowl and Dragons soar in my dreams...
> _______________________________________________
> UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub
> http://lists.evdl.org/listinfo.cgi/ev-evdl.org
> For EV drag racing discussion, please use NEDRA 
> (http://groups.yahoo.com/group/NEDRA)
> 