I just completed the bias adjustments per ECO-027. As I went through it, the only question I had was what could one expect to be a normal current reading for the final adjustment. The example used 1.433 as a typical reading and mine turned out to be 1.805. I am assuming that it's within specifications even though it's about a half an amp high.
 
I thought that as long as I was there I would check the final bias setting and it was right on.
 
It's a piece of cake for anyone contemplating it.
 
--Larry W8ER 