"There is a known delay on PTT in HRD when PTT is controlled by CAT via a 
virtual com port pair"

That behavior has been reported by many people.


-Tim


-----Original Message-----
From: flexradio-boun...@flex-radio.biz 
[mailto:flexradio-boun...@flex-radio.biz] On Behalf Of Eddy Van de Velde
Sent: Friday, September 11, 2009 7:03 PM
To: flexradio@flex-radio.biz
Subject: [Flexradio] Delay on PTT with HRD.

There is a known delay on PTT in HRD when PTT is controlled by CAT via a 
virtual com port pair. No delay when PTT is controlled by a second virtual com 
port pair and all other CAT control via the first pair.

It was thought that Vcom or com0com might be the problem. I have tried the 
Eltima VSPD now and the PTT delay is exactly the same.

So, until a possible fix in HRD, I keep using two virtual serial com port pairs.

73

Eddy ON5UQ.