i second that, no ip icmp redirects - in global config mode or no ip redirect - in interface config mode
and you are good to go. Tudor -------------------------------------------- On Wed, 5/25/16, Mike Allen <[email protected]> wrote: Subject: Re: [f-nsp] MLXe slow on 10G doing inter-vlan routing To: "George B." <[email protected]> Cc: [email protected] Date: Wednesday, May 25, 2016, 1:07 AM Turn off ICMP redirects. Common problem in one arm routing configs. IMO it should be the default setting but it's not. Mike On May 24, 2016 2:00 PM, "George B" <[email protected]> wrote: Do you notice the same behavior with both UDP and TCP streams? On Tue, May 24, 2016 at 1:42 PM, Steven Raymond <[email protected]> wrote: MLXe, very lightly loaded, with only one card BR-MLX-10Gx8-X. Simplest of configuration, layer 2 link with VE interfaces. During inter-vlan routing where the ingress traffic and egress traffic are on the same port, say e1/2, the input traffic level will be fine, but the output traffic is effectively maxed out at about 50Mbps (on a 10GigE port). Shift hosts around so that the egress is a different port on the same card, bang problem gone and full expected traffic rates achieved. Tried numerous code versions, from 05800a to 05900a to 06000. No improvement. Of course tried rebooting, new optics, new cabling. No errors incrementing on the interface. This is the silliest dumb problem in a long time. Any ideas are appreciated. Thanks! _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp -----Inline Attachment Follows----- _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp