Follow-up Comment #18, sr #110963 (project freeipmi): Actually I just noticed something in your out of band debug output.
``` >> Sending IPMI command payload >> netfn : 0x04 >> command : 0x2d BUILDING A v2 COMMAND Local RqAddr 0x20 transit 0:0 target 0x20:0 bridgePossible 1 << IPMI Response Session Header << Authtype : RMCP+ << Payload type : IPMI (0) << Session ID : 0xa0a2a3a4 << Sequence : 0x00000309 << IPMI Msg/Payload Length : 32 << IPMI Response Message Header << Rq Addr : 81 << NetFn : 05 << Rq LUN : 0 << Rs Addr : 20 << Rq Seq : 0f << Rs Lun : 0 << Command : 2d << Compl Code : 0x00 ``` This is the "get sensor reading" command, and it apparently doesn't return an error (completion code == 0). Could you do the out of band --debug --bridge-sensors output again? Your debug output of that before didn't connect to the server. i.e. ipmi-sensors -r NUMBER --debug --bridge-sensors -h host -u user -p password _______________________________________________________ Reply to this item at: <https://savannah.gnu.org/support/?110963> _______________________________________________ Message sent via Savannah https://savannah.gnu.org/