Hi everybody,
I am trying to process high res monkey scans in FreeSurfer (voxel size
0.31 x 1 x 0.31 mm). For converting them I use:
mri_convert rawdata.img orig.mgz -iis 0.31 -ijs 1 -iks 0.31 -cm
But I actually get a very small image in tkmedit. Further, moving each
slice in any of the three directions give a volume index change of 1
and voxel RAS change of 3 (i.e. on the coronal slice number 128, the
volume index 128 128 128 is equivalent to the volume RAS 0 0 0; going
to the coronal slice 129 without moving the cursor will give the
volume index 128 128 131, and RAS 0 1 0).
Since RAS are the coordinates in millimeter, I actually expected that
any change of slice would be accompanied by a 0.31 change on RAS and
variation of 1 on volume index... Is there any basic step that I missed?
Thank you very much,
Marie Schaer
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer