Hi Tanja,
Can you send us an image? Is parahippocampal white matter significantly darker 
than 110?
Bruce



On Feb 21, 2011, at 6:41 AM, Tetiana Dadakova <tetian...@gmail.com> wrote:

> Dear Freesurfer users,
> 
> For some of my subjects Freesurfer strongly overestimates hippocampus'
> volume. Is there any way to fix the segmentation of hippocampus by
> e.g. adding some control points (like for white matter here
> http://surfer.nmr.mgh.harvard.edu/fswiki/FsTutorial/ControlPoints)?
> 
> Thank you,
> Tanja.
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
> 
> 

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer