Dear FreeSurfer experts,

when I run e.g.:

mri_nu_correct.mni --i orig.mgz --mask brainmask.mgz --o nu.mgz --n 1 
--proto-iters 1000 --uchar transforms/talairach.xfm —cm

where orig.mgz and brainmask.mgz have 577 x 577 x 577 voxels, there is an error:

$Id: mri_segstats.c,v 1.109 2014/10/17 19:31:46 greve Exp $
cwd 
cmdline mri_segstats --id 1 --seg ./tmp.mri_nu_correct.mni.15003/ones.mgz --i 
orig.mgz --sum ./tmp.mri_nu_correct.mni.15003/sum.junk --avgwf 
./tmp.mri_nu_correct.mni.15003/input.mean.dat 
sysname  Linux
hostname shuki
machine  x86_64
user     nzaretsk
UseRobust  0
Loading ./tmp.mri_nu_correct.mni.15003/ones.mgz
Loading orig.mgz
ERROR: dimension mismatch between input volume and seg
input 577 577 577
seg   578 578 578


I have checkt and it appears that 
mri_convert orig.mgz orig_out.mgz -cm
results in orig_out.mgz having one voxel more, e.g. 578 x 578 x 578, instead of 
 577 x 577 x 577

This does not happen when one omits the “-cm" flag, or when the input volume is 
578 x 578 x 578.

Is this a bug, or do the image dimensions have to be even for some reason?

Thanks!
Natalia






_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

Reply via email to