Hi Elijah - It looks to me like the forceps major had the same problem for both MNI and CVS in this subject, right? This subject has a relatively thin and somewhat convoluted forceps major, so you can try increasing the number of control points, say from 7 to 8. (But I'd try reinitialization first, before changing anything.)
Hope this helps, a.y On Thu, 18 Aug 2016, Elijah Mak wrote:
Dear Anastasia, I have also uploaded the file with the problem (22995_EM.zip), and this is how my config file looks like after modifications: set subjlist = (22995) set pathlist = (fmajor_PP) set ncpts = (7) set reinit = (1) Thanks again! Best Wishes, Elijah -- Elijah Mak PhD Candidate | Psychiatry University of Cambridge Trinity College, Cambridge, CB2 1TQ
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.