External Email - Use Caution        

Hello I have tried using a greater threshold,(original 0.05) now 0.001 sill
the result persist.
Is there a way to threshold over a specific region?

 Total Cortical Surface Area *65416.6 (mm^2)*
# FixMNI = 0
# ClusterNo  Max   VtxMax   Size(mm^2)  MNIX   MNIY   MNIZ    CWP
CWPLow    CWPHi   NVtxs   Annot
   1      -44.154    9733 * 66963.16*     -4.9  -47.1   29.6  0.00020
0.00000  0.00040  131785  isthmuscingulate





On Thu, Jan 10, 2019 at 1:42 PM Azeez, Azeezat <ak...@njit.edu> wrote:

>
> Hello ,
> I have results for my mri_glmfit-sim. I find a significant results in my
> cache.th20abs.sig.cluster.summary.
> Yet, the cluster size of the significant cluster is almost the size of the
> total cortical surface area. I am not sure what to make of this any help
> would be helpful.
>
> # Total Cortical Surface Area 65416.6 (mm^2)
> # ClusterNo  Max   VtxMax   Size(mm^2)  MNIX   MNIY   MNIZ    CWP
> CWPLow    CWPHi   NVtxs   Annot
>    1      -44.154    9733  55204.38     -4.9  -47.1   29.6  0.00020
> 0.00000  0.00040  108257  isthmuscingulate
>
>
> --
> Azeezat Azeez
>
>

-- 
Azeezat Azeez
PhD Student
Department of Biomedical Engineering || New Jersey Institute of Technology
Graduate School of Biomedical Sciences || Rutgers University
E: ak...@njit.edu
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to