External Email - Use Caution        

Thank you Douglas. So that means I can basically use either one for
freesurfer to native space conversion, is that right? Is there any case in
which label2vol should definitely be used instead of vol2vol?
Best regards,
Sam


On Tue, Apr 16, 2019 at 10:12 PM Greve, Douglas N.,Ph.D. <
dgr...@mgh.harvard.edu> wrote:

> Are they exactly the same? Try
> mri_diff file1.mgz file2.mgz
> I would not expect them to be all that different, just a few voxels here
> and there
>
> On 4/16/19 3:47 PM, Sam W. wrote:
> >
> >         External Email - Use Caution
> >
> > Hi,
> > In a Freesurfer help webpage it says that to convert an image (eg
> > brain.mgz) from freesurfer to anatomical native space (eg rawavg.mgz)
> > we should use mri_vol2vol, but for a segmentation (aseg.mgz) we should
> > use mri_label2vol. I converted the aseg.mgz of bert using both vol2vol
> > and label2vol and found no difference - The resulting output images
> > look exactly the same. Is there really an advantage of using label2vol
> > instead of vol2vol?
> > Thanks!
> > Sam
> >
> > _______________________________________________
> > Freesurfer mailing list
> > Freesurfer@nmr.mgh.harvard.edu
> > https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
>
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to