Check that the interface in backup state on the first FW is monitoring the 
correct interfaces.  Took me two hours to find this one when it happened to 
me - it was eth-s1p2 instead of eth-s1p3 in a long list of monitored 
interfaces.
Check that the priorities are all correct.

hermit1


At 12:28 PM 7/3/00 -0400, Tom Sevy wrote:

>Two IP440's, VRRP running.
>
>Two quad eth cards in each.
>
>5 interfaces active, paired monitered circuits including VRRP circuit.
>
>If both IP440's are up & running, 4 interfaces on first FW are in master
>state, one in backup, and opposite on 2nd FW.
>
>Any suggestions?



================================================================================
     To unsubscribe from this mailing list, please see the instructions at
               http://www.checkpoint.com/services/mailing.html
================================================================================

Reply via email to