About the unused slots, it doesn't seems to be the problem.

When I add the 2 unused slots to my schematics and link theirs input pins to
ground and output pin to NC symbol, drc2 removes the warning but the
spice-sdb give me more "Invalid wanted_pin passed to get-nets [unknown]"

I've already use slots in another circuit without any problem.

Ludovic

On Sat, Aug 16, 2008 at 4:51 PM, Peter Clifton <[EMAIL PROTECTED]> wrote:

> On Sat, 2008-08-16 at 09:26 -0400, John Doty wrote:
> > On Aug 16, 2008, at 2:55 AM, Ludovic SMADJA wrote:
> >
> > > WARNING: Unused slot 3 of uref U2
> > > WARNING: Unused slot 4 of uref U2
> >
> > I believe that unused slots are poison to the way spice-sdb works.
> > For a slotted component, it expects that the model will implement all
> > slots. Since pins are positional in SPICE netlists, it needs to list
> > every pin on the component.
>
> Perhaps for the spice backend, but IIRC, spice-sdb renames each slot, so
> U2 becomes.
>
> U2.1
> U2.2
> U2.3
> U2.4
>
> e.g. 4 components instantiated. I might be wrong in the fine-print though.
>
> --
> Peter Clifton
>
> Electrical Engineering Division,
> Engineering Department,
> University of Cambridge,
> 9, JJ Thomson Avenue,
> Cambridge
> CB3 0FA
>
> Tel: +44 (0)7729 980173 - (No signal in the lab!)
>
>
>
> _______________________________________________
> geda-user mailing list
> geda-user@moria.seul.org
> http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
>



-- 
Ludovic SMADJA

_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user

Reply via email to