> On Sun, 12 Jan 2014 17:28:42 +0100 (CET) > [email protected] wrote: > > > > What is the time resolution in GHDL, maximum number of simulation > > > time > > > steps, and maximum simulation time value? > > > > See > > http://ghdl.free.fr/ghdl/Simulation-options.html#Simulation-options > > > > The time resolution is 1ps, maximum simulation time is time'high > > and > > the default maximum number of delta is 5000. > > > > Thanks! Assuming the model isn't ringing in delta time and always > stabilizes to a steady state (well) within 5000 delta cycles, then > since: > > TYPE time IS RANGE -2_147_483_647 TO 2_147_483_647 > > I guess that means there are 2_147_483_647 simulation time steps > available. What happens when the simulator reaches time'high?
Simulation stops. That's the usual way to stop simulation. Tristan. _______________________________________________ Ghdl-discuss mailing list [email protected] https://mail.gna.org/listinfo/ghdl-discuss