My second guess on the LOOP+6^XQOR1 problem is that you have a OPTION being executed somehow that has an ENTRY ACTION that has a line^routine reference that is invalid.
 
Your mail problem most likely is that a message is trying to be sent to a remote domain that is open and should not be.

 
On 10/26/05, Usha <[EMAIL PROTECTED]> wrote:
After rebuilding all the primary and secondary menu options, the following is the output of D ^XTER
 
EHR>D ^XTER
 
 
In response to the DATE prompt you can enter:
     'S' to specify text to be matched in error or routine name
 
 
6 errors logged on 10/26/2005
  6)  <READ>L3+1^XMC1A                10:44:44  EHR,EHR     2028  |TCP|2078
  5)  <NOLINE>LOOP+6^XQOR1            10:44:05  EHR,EHR     2560  //./nul:2560
  4)  <READ>L3+1^XMC1A                10:42:54  EHR,EHR     2028  |TCP|2078
  3)  <READ>L3+1^XMC1A                10:41:03  EHR,EHR     2028  |TCP|2078
  2)  <NOLINE>LOOP+6^XQOR1            10:40:35  EHR,EHR     2556  //./nul:2556
  1)  <READ>L3+1^XMC1A                10:39:14  EHR,EHR     2028  |TCP|2078

Reply via email to