"Dizzy J." wrote:
>
> Hi all,
>
> got a few more questions on moving patters from cakewalk to the rm1x.
>
> Ill ask them outright, with details below...
>
> 1)has anyone had a problem loading up midi format 1 songs from cakewalk as
> a pattern? a 16 measure song gets loaded up as 110 measures (in pattern
> mode). midi format 0 doesnt have this problem.
The same thing happened to me with midi files exported from Opcode
Vision DSP. I had to use the split-phrase job to cut the phrases to the
correct length. I think I got patterns that were 55 measures long, while
the midi files were only 8 measures long. There definitely was no data
in the midi file after measure 8. I haven't tried this with midi format
0 yet.
--
Peter de Waal
Department Mathematical Models and Methods e-mail: [EMAIL PROTECTED]
National Aerospace Laboratory NLR tel: +31 20 5113626
P.O.Box 90502, 1006 BM Amsterdam fax: +31 20 5113210
The Netherlands