Mike Myers wrote:
> 
> Steve:
> 
> 
> I do know that the formatter in IPCS (TCBEXIT IECDAFMT - at least I
> think that's the right exit - if not, then it's probably IECIOFMT) will
> display the DCB as a block of data, but does not format its fields either.
> 
> Mike Myers

IP SUMM FORMAT will display DCB info, here's the one for SYSMDUMP:

DATA MANAGEMENT,CONTROL BLOCKS FOR OPEN DATA SETS
***DCB,AT LOCATION 7ADF68       (BSAM)                                          
DASD
+0   ,  DCBE  7F424B7C     KEYCN 00     FDAD  000000 076F0005 02    DVTBA EF6026
+10  ,  KEYLE 00  DEVT 2F  TRBAL 184E   BUFCB 00000001  BUFL 0000   DSORG 4000  
    IOBAD 0050C000
+20  ,  EODAD 86000001     RECFM 98     EXLST 7ADFC4    TIOT 048C   MACRF 0020  
    IFLGS 00     DEBA  7B516C
+30  ,  OFLGS 92   BEEA68  OPTCD 00           E00908    IOBL 0A      SYNA 
000001    CIND  0000   BLKSI 6180
+40  ,  WCPO  30013030     IOBA  0050C070 NCP 04       EOBRA D79658  EOBW 
00D79658  DIRCT 0000   LRECL 1040
+54  ,  POINT 00000001

-- 