Just a wild guess....... You mentioned there is Z/OS 1.6 system which is running without these problems and the system which fails is a Z/OS 1.12 system. Are these two systems sharing the RACF database? Have they run together before the ESS problem?
If they are sharing the RACF database and this might be the first IPL of the Z/OS 1.12 system, then I would look at the results of the RACF database template upgrade job. It might be possible the RACF database has not been upgraded to the 1.12 level of the templates and RACF could be complaining about the downlevel database. Just my thoughts....... ----- Original Message ----- From: "jagadishan perumal" <jagadish...@gmail.com> To: IBM-MAIN@bama.ua.edu Sent: Friday, September 23, 2011 12:15:20 AM Subject: RACF server disabled During IPL Hi, After ESS battery change , unfortunately due to power drip cluster was restarted which led to abnormal shutdown of ZOS 1.12. After the hardware fix , we did a POR and tried reloading the OS ,we found the below messages in the console while IPLing which stopped further system proceeding. ERROR MESSAGES: IRR418I RACF product disabled : IRRSSI00 ended BPX006E OMVs is pending for security product AXR0501E System REXX is waiting for Security product. I have even checked IFAPRDXX parmlib and the security server option is Enabled : PRODUCT OWNER('IBM CORP') NAME('z/OS') ID(5694-A01) VERSION(*) RELEASE(*) MOD(*) FEATURENAME('SECURITY SERVER') STATE(ENABLED) Details on Version : Z/OS V1R12. RSU1011 Could anyone please suggest your experts comment. Regards, Jags ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html