Cheryl, Did you review the SNA messages and codes, that's your fist step..sense 8002 is a resource not available, maybe a timing issue with the IPL ...
Scott ford www.identityforge.com On May 14, 2012, at 12:21 PM, "Meehan, Cheryl" <cmee...@cswg.com> wrote: > Greetings- > > We upgraded our operating system to z/os 1.11 last fall. We have IPL'd > our Production System twice since then, and each time, we have caused > our AUTO1 task to fail on our Test System. Last week, we IPL'd our test > system, and the AUTO1 task dropped on our Production system. Once > recovered, we IPL'd our Test system several more times, and never lost > AUTO1. > > The messages that we are seeing are for our EE link between the two > system to go down, ( as we are IPLing. . . . ) > and then these Messages: > > MVS2 12134 01:17:32.40 STC35551 00000281 DSI769I MVS02 RPL_EXIT > APPCCMD RECEIVE FAILED, LUNAME = MVS01, QUALIFY = > X'11', FEEDBACK = > (X'4C',X'00',X'80020000') > MVS2 12134 01:17:32.40 STC35551 00000281 DSI769I MVS02 RPL_EXIT > APPCCMD SEND FAILED, LUNAME = MVS01, QUALIFY = > X'07', FEEDBACK = > (X'4C',X'00',X'80020000') > MVS2 12134 01:17:32.40 STC35551 00000281 DWO575I RMTCMD TERMINATED > ON CSNET.MVS01 WITH SENSE: X'08A80012' > MVS2 12134 01:17:32.40 STC35551 00000281 DSI769I MVS02 RPL_EXIT > APPCCMD ALLOC FAILED, LUNAME = MVS01, QUALIFY = > X'1F', FEEDBACK = > (X'04',X'00',X'087D0001') > MVS2 12134 01:17:32.44 STC35551 00000290 IEA631I OPERATOR AUTO12 > NOW INACTIVE, SYSTEM=MVS2 , LU=AUTO1 > > If anyone else has had this issue, I would appreciate your insight. > > Cheryl Meehan > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN