Scott- The reason the resource is not available is because the system it is attached to is coming down. Which makes sense, because we're IPLing it.
We have never had this issue prior to this version of the operating system. We do not believe we have any cross LPAR Tasks running that we have been able to find thus far. We plan to check next IPL for any cross netview sessions, and see if a disconnect is necessary, but it has never been required in the past. Cheryl -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Scott Ford Sent: Monday, May 14, 2012 1:36 PM To: IBM-MAIN@bama.ua.edu Subject: Re: Netview Question Cheryl, Did you review the SNA messages and codes, that's your fist step..sense 8002 is a resource not available, maybe a timing issue with the IPL ... Scott ford www.identityforge.com On May 14, 2012, at 12:21 PM, "Meehan, Cheryl" <cmee...@cswg.com> wrote: > Greetings- > > We upgraded our operating system to z/os 1.11 last fall. We have > IPL'd our Production System twice since then, and each time, we have > caused our AUTO1 task to fail on our Test System. Last week, we IPL'd > our test system, and the AUTO1 task dropped on our Production system. > Once recovered, we IPL'd our Test system several more times, and never > lost AUTO1. > > The messages that we are seeing are for our EE link between the two > system to go down, ( as we are IPLing. . . . ) and then these > Messages: > > MVS2 12134 01:17:32.40 STC35551 00000281 DSI769I MVS02 RPL_EXIT > APPCCMD RECEIVE FAILED, LUNAME = MVS01, QUALIFY = > X'11', FEEDBACK = > (X'4C',X'00',X'80020000') > MVS2 12134 01:17:32.40 STC35551 00000281 DSI769I MVS02 RPL_EXIT > APPCCMD SEND FAILED, LUNAME = MVS01, QUALIFY = > X'07', FEEDBACK = > (X'4C',X'00',X'80020000') > MVS2 12134 01:17:32.40 STC35551 00000281 DWO575I RMTCMD TERMINATED > ON CSNET.MVS01 WITH SENSE: X'08A80012' > MVS2 12134 01:17:32.40 STC35551 00000281 DSI769I MVS02 RPL_EXIT > APPCCMD ALLOC FAILED, LUNAME = MVS01, QUALIFY = > X'1F', FEEDBACK = > (X'04',X'00',X'087D0001') > MVS2 12134 01:17:32.44 STC35551 00000290 IEA631I OPERATOR AUTO12 > NOW INACTIVE, SYSTEM=MVS2 , LU=AUTO1 > > If anyone else has had this issue, I would appreciate your insight. > > Cheryl Meehan > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to lists...@bama.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN