Hi Peter,

In respect of:

"Enterprise COBOL compiler v3.4.

Am pretty sure someone else must have hit this. I have hit the 100 char (I 
think ?) limit for the opts passed to the compiler via the Parm setting in the 
JCL.

For the Enterprise PL1 compiler I solved this by setting PARM='+DD:OPTIONS' in 
the JCL and then putting the compiler opts in the dd named OPTIONS. 

Is there a way for doing this with the Enterprise COBOL Compiler ? ... I have 
been looking through the manuals, and have not found anything ?"

Can you not use the CONTROL or CBL statement ahead of the IDENTIFICATION 
DIVISION as discussed in the Programmig Guide.