Use IEFU29 - the one in SAMPLIB has code to handle either. Minor 
modifications to get it working.

Shane ...

IBM Mainframe Discussion List <IBM-MAIN@bama.ua.edu> wrote on 26/03/2008 
06:45:11 AM:

> Yep - I had one setup and working.  Then I changed the name of my MANx
> datasets, and then the message number changed!
> Changed from using SYS1.MANx  datasets to SYS1.MISZOS.MANx it appears 
that
> the dump message has changed!?!?!
> From:
> *IEE362A SMF ENTER DUMP FOR SYS1.MAN2 ON PCAT01
> 
> To:
> *IEE391A SMF ENTER DUMP FOR DATA SET ON VOLSER PCAT01, 748
>                  DSN=SYS1.MISZOS.MAN2

----------------------------------------------------------------------