That was our experience too.  We have to run with ALL31(OFF).  We have lots of 
very old Assembler, OS/VS COBOL, COBOL II, etc.  Mission critical stuff and 
nobody and no budget to upgrade it.   We tested with ALL31(ON) and the programs 
started out fine, the old Assembler ran fine, but it could not return, so the 
processes failed.

Linda Mooney

-------------- Original message -------------- 
From: Ted MacNEIL <[EMAIL PROTECTED]> 

> >The information I provided was from the current LE manuals. And I have 
> confirmed this by running some tests. ALL31(OFF) is needed if there are any 
> AMODE 24 routines. 
> 
> I don't have any proof, other than experience. 
> It was done under a (proprietry) performance study conducted by IBM on our 
> behalf, along with approximately 200 other recommendations. 
> It worked, and we had some very creaky old COBOL code. 
> OS/390 2.10, CICS/TS 1.3. 
> z/OS 1.4 CICS/TS 1.3 & 2.2 
> z/OS 1.7 CICS/TS 2.2 
> 
> I didn't do the implementation. 
> I was the project co-ordinator. 
> I believed the CICS people (and IBM) when they said it had been done. 
> 
> - 
> Too busy driving to stop for gas! 
> 
> ---------------------------------------------------------------------- 