Review the system log during the initial IPL process and see what actually 
happened.

Mark Jacobs

Sent from ProtonMail, Swiss-based encrypted email.

GPG Public Key - 
https://api.protonmail.ch/pks/lookup?op=get&search=markjac...@protonmail.com

‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐

On Saturday, October 3rd, 2020 at 2:54 PM, Gadi Ben-Avi <gad...@malam.com> 
wrote:

> HI,
>
> I went into work this evening to IPL our production LPAR's
>
> When I IPL's one system, it used IEASYS00 instead of the system specific 
> IEASYS0B.
>
> The LOAD member for the LPAR says
>
> SYSPARM 0B.
>
> The only thing that has changed recently is that we started using IEASYM for 
> the first time ever.
>
> We specified IEASYM 00 in LOADxx and there is an IEASYM00 member in 
> SYS1.PARMLIB that adds a static symbol.
>
> Could this be causing the problem?
>
> We are running z/OS v2.3
>
> Gadi
>
> ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
>
> For IBM-MAIN subscribe / signoff / archive access instructions,
>
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to