You cannot, 00 is always used as the base, you can only concatenate over-rides to it. LOADxx and IEASYMxx will concatenate to 00, and WTOR response will over-ride LOADxx and IEASYMxx -- but I know of no way to eliminate 00 as a base. Normally 0B would have all the needed over-ride values for 00 making it effectively the same as "only 0B" :)
On Tue, Oct 6, 2020 at 3:18 PM Gadi Ben-Avi <gad...@malam.com> wrote: > HI, > The output from D IPLINFO,SYSP is > IEE255I SYSTEM PARAMETER 'SYSP': (0B,00) > I would like it to be only 0B > > Gadi > > -----Original Message----- > From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf > Of Peter Relson > Sent: Sunday, October 4, 2020 4:46 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: IEASYS problem > > What does DISPLAY IPLINFO,SYSP show? > > Peter Relson > z/OS Core Technology Design > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN