Classification: Public

The message is pretty clear: Your VTMF.LINKLIB is a PDSE that contains program 
objects, and you can't put those into a PDS - the target library 
(S172.SYSL.ENDEVOR.V17R0 in this case) MUST be a PDSE. 

At a wild guess, based purely on the member name being copied (M10SNCOB here), 
it's a COBOL program that's been compiled under COBOL v5 or later, and so 
requires a PDSE as the target library for the executable.

Andy Styles
z/Series System Programmer

-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Weizman arbel
Sent: 23 November 2021 08:00
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: iebcopy problem copy load from pdse to pds

*** This email is from an external source - be careful of attachments and 
links. Please report suspicious emails ***

hello ,

There is a suggestion on how to do ?
It brings me back this error :

IEW2606S 4B39 MODULE INCORPORATES VERSION 3 PROGRAM OBJECT FEATURES AND CANNOT 
BE SAVED IN LOAD MODULE FORMAT.


IEB1135I IEBCOPY  FMID HDZ2240  SERVICE LEVEL UJ00519  DATED 20190816 DFSMS 02.0
IEB1035I S172IEB1  IEBCOPY1 09:42:53 TUE 23 NOV 2021 PARM=''                    
  COPY  OUTDD=SYSUT2,INDD=((SYSUT1,R)),LIST=YES                                 
  SELECT MEMBER=(M10SNCOB)                                                      
IEB1013I COPYING FROM PDSE  INDD=SYSUT1   VOL=TMD002 DSN=VMTF.LINKLIB           
IEB1014I           TO PDS  OUTDD=SYSUT2   VOL=USL003 DSN=S172.SYSL.ENDEVOR.V17R0
IGW01207E BINDER DETECTED AN ERROR WHILE PROCESSING MEMBER M10SNCOB             
.  BINDER RETURN CODE = X'0000000C' REASON CODE = X'83000422'                   
IGW01550I 0 OF 1 SPECIFIED  MEMBERS WERE COPIED                                 
IEB1130W AN ERROR MESSAGE FROM FAMS PROCESSING APPEARS ABOVE -- DIAGNOSTIC INFOR
IEB151I JOB HAS TERMINATED WITH ERROR(S)                                        
IEB147I END OF JOB - 4 WAS HIGHEST SEVERITY CODE   

thanks , weizman                             

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Lloyds Banking Group plc. Registered Office: The Mound, Edinburgh EH1 1YZ. 
Registered in Scotland no. SC95000. Telephone: 0131 225 4555.

Lloyds Bank plc. Registered Office: 25 Gresham Street, London EC2V 7HN. 
Registered in England and Wales no. 2065. Telephone 0207626 1500.

Bank of Scotland plc. Registered Office: The Mound, Edinburgh EH1 1YZ. 
Registered in Scotland no. SC327000. Telephone: 03457 801 801.

Lloyds Bank Corporate Markets plc. Registered office: 25 Gresham Street, London 
EC2V 7HN. Registered in England and Wales no. 10399850.

Scottish Widows Schroder Personal Wealth Limited. Registered Office: 25 Gresham 
Street, London EC2V 7HN. Registered in England and Wales no. 11722983.

Lloyds Bank plc, Bank of Scotland plc and Lloyds Bank Corporate Markets plc are 
authorised by the Prudential Regulation Authority and regulated by the 
Financial Conduct Authority and Prudential Regulation Authority.

Scottish Widows Schroder Personal Wealth Limited is authorised and regulated by 
the Financial Conduct Authority.

Lloyds Bank Corporate Markets Wertpapierhandelsbank GmbH is a wholly-owned 
subsidiary of Lloyds Bank Corporate Markets plc. Lloyds Bank Corporate Markets 
Wertpapierhandelsbank GmbH has its registered office at Thurn-und-Taxis Platz 
6, 60313 Frankfurt, Germany. The company is registered with the Amtsgericht 
Frankfurt am Main, HRB 111650. Lloyds Bank Corporate Markets 
Wertpapierhandelsbank GmbH is supervised by the Bundesanstalt für 
Finanzdienstleistungsaufsicht.

Halifax is a division of Bank of Scotland plc.

HBOS plc. Registered Office: The Mound, Edinburgh EH1 1YZ. Registered in 
Scotland no. SC218813.



This e-mail (including any attachments) is private and confidential and may 
contain privileged material. If you have received this e-mail in error, please 
notify the sender and delete it (including any attachments) immediately. You 
must not copy, distribute, disclose or use any of the information in it or any 
attachments. Telephone calls may be monitored or recorded.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to