Food for thought. You might investigate using the ADRDSSU exit
available to C:D.
Not only does it allow specifying target dataset(s) SMS classes, it
even allows copying whole volumes or dsname-masked groups of files
between z/OS systems.
Michael
At 07:50 AM 1/31/2024, Gadi Ben-Avi wrote:
Hi,
I am trying to transfer a file using Connect:Direct from one z/OS
system to another.
I need to specify both STORCLAS and DATACLAS.
This is what I am writing:
CPYSEQ PROCESS -
SNODE=RTST
COPY1 COPY -
FROM (DSN=G120NTN.KVTNKSP.UNLOAD -
DISP=SHR -
PNODE -
) -
TO (DSN=G120NTN.KVTNKSP.UNLOAD -
DISP=(NEW,CATLG) -
SPACE=(CYL,(999,9999),RLSE) -
SYSOPTS="STORCLAS=RKF1 DATACLAS=EXT" -
SNODE -
)
And I keep getting errors.
How to I specify more than one parameter in SYSOPTS. I've tried
writing a comma between the parameters with the same results.
Thanks
Gadi
----------------------------------------------------------------------