Classification: Confidential Disabled job account codes?
-----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Ramsey Hallman Sent: Tuesday, April 22, 2025 4:02 PM To: [email protected] Subject: Re: IEFC452I !?! [CAUTION: This Email is from outside the Organization. Unless you trust the sender, Don’t click links or open attachments as it may be a Phishing email, which can steal your Information and compromise your Computer.] The version prior to 3.1 is 2.5 of z/OS. From the error message, it does not necessarily have to be the job name. It could be other JCL issues. IEFC452I text - JOB NOT RUN - JCL ERROR Explanation Depending on the message text, one of the following: JOBFAIL The error was detected on a JOB statement and the job name is not known. INVALID The system detected an error in a JOB or other JCL statement, and the job name (the label on the JOB statement) is invalid. jobname The system detected an error in a JCL statement, or the job was cancelled while on the input queue. procstep The procedure was specified in the first operand of a START command. In this case, either the procedure was not found in SYS1.PROCLIB or, if found, the procedure had an error in a JCL statement. Message IEE122I or IEE132I will always follow this message. The error message appears in the SYSOUT data set. This message can also be issued for various environmental errors, such as an error occurring while trying to read a record from the JCL text data set or an I/O error occurring while trying to get procedure statements. System action If the operator cancelled the job, all steps of the job, beginning with the step currently being processed, will be ended. Otherwise, the job will not be initiated; no steps will be processed. If procstep appears, the START command will not be run. Operator response If the job name appears, none. If procstep appears, either reenter the START command with the correct procedure name, or, if the procedure name is correct, notify the application programmer. Programmer response Check the procedure for errors. Source Converter Module IEFCNJRT Routing code 2,10 Descriptor code 4 On Tue, Apr 22, 2025 at 3:53 PM Steve Thompson <[email protected]> wrote: > Hi all, got a weird one. > > I am running the same JOB over and over processing different files. > All that changes is the suffix on an output DSN that identifies the > DATA cycle of this execution, and the SORTIN DD/DSN contents (some > have a single file some have up to 15 files). Data may be on disk or > tape. TPM holds the job until HSM restore completes if that is why the > data is on tape. > > I would love to show you the JCL, but I am NOT allowed. Suffice to say > security controls. > > I have taken the JOB cards off another one of these JOBs that ran > successfully and replaced the JOB card (one from a prior submission of > this specific JOB). > > And I still get this error. The last thing it says is 748. > Since I don't have 700 JCL statements, that isn't the problem. > Besides this is supposedly a JOB card error!! > > BTW, sometimes the files I have been told to pick disappear before I > can get the JCL updated and submitted, so I do get file not found > errors. But this is not the issue here. > > I have a copy of the full tech library for the Version of z/OS just > prior to 3.1 (can't remember the V/R). And it is not helping me with > this. > > -- > Thanks for your help/insight in advance. > > Steve Thompson > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ::DISCLAIMER:: ________________________________ The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. ________________________________ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
