On Tue, 21 Oct 2025 09:51:56 -0500, Mike Schwab <[email protected]> wrote:

>Sometimes tape recycles take a very long time and operations cancel it
>to performan IPL.
>
>On Tue, Oct 21, 2025 at 7:44 AM Chalk, Shelia <[email protected]> wrote:
>
>>   ABEND SYSTEM CODE=222 ASID=0058

S222 abends are typically from a console command which is typically not 
displayed in the joblog. Look in the job log for where the cancel command 
originated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN