I guess my point was that she needed to find whoever issued the CANCEL and
ask why they did it.

(DFSMS doesn't issue CANCELs internally, does it?)

On Tue, Oct 21, 2025 at 3:00 PM Pommier, Rex <
[email protected]> wrote:

> I would venture a guess that Shelia is more interested in why the IGD300I
> message appeared than what causes an S222 abend.  Mike gave a good
> description of various reasons the IDG message appeared.
>
> Rex
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf
> Of Jon Perryman
> Sent: Tuesday, October 21, 2025 2:47 PM
> To: [email protected]
> Subject: [EXTERNAL] Re: IGD300i Message
>
> On Tue, 21 Oct 2025 09:51:56 -0500, Mike Schwab <[email protected]>
> wrote:
>
> >Sometimes tape recycles take a very long time and operations cancel it
> >to performan IPL.
> >
> >On Tue, Oct 21, 2025 at 7:44 AM Chalk, Shelia <[email protected]> wrote:
> >
> >>   ABEND SYSTEM CODE=222 ASID=0058
>
> S222 abends are typically from a console command which is typically not
> displayed in the joblog. Look in the job log for where the cancel command
> originated.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>


-- 
Jay Maynard

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to