I will add that if this was from a DFHSM task. Canceling DFHSM tasks is not 
really a good idea and can result in CDS inconsistencies.

> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On
> Behalf Of Pommier, Rex
> Sent: Tuesday, October 21, 2025 1:00 PM
> To: [email protected]
> Subject: Re: [EXTERNAL] Re: IGD300i Message
> 
> I would venture a guess that Shelia is more interested in why the IGD300I
> message appeared than what causes an S222 abend.  Mike gave a good
> description of various reasons the IDG message appeared.
> 
> Rex
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On
> Behalf Of Jon Perryman
> Sent: Tuesday, October 21, 2025 2:47 PM
> To: [email protected]
> Subject: [EXTERNAL] Re: IGD300i Message
> 
> On Tue, 21 Oct 2025 09:51:56 -0500, Mike Schwab
> <[email protected]> wrote:
> 
> >Sometimes tape recycles take a very long time and operations cancel it
> >to performan IPL.
> >
> >On Tue, Oct 21, 2025 at 7:44 AM Chalk, Shelia <[email protected]> wrote:
> >
> >>   ABEND SYSTEM CODE=222 ASID=0058
> 
> S222 abends are typically from a console command which is typically not
> displayed in the joblog. Look in the job log for where the cancel command
> originated.
> 
> ----------------------------------------------------------------------