> I did for SETSMS for COMMDS there was no response at all, but for SCDS and > ACDS i got the below : > > setsms acds(system.zt01.acds) > IGD068I ACDS SYSTEM.ZT01.ACDS SPECIFIED IS THE > SAME AS THE ACTIVE ACDS - COMMAND IS REJECTED > > > setsms scds(system.zt01.scds) > IGD056I ACDS SYSTEM.ZT01.ACDS NOT FOUND > IGD052I REQUEST DENIED - NO ACTIVE CONFIGURATION >
It seems the ACDS doesn't exist or is not in that catalog. I usually have trouble copying the COMMDS, so I just define a new one and use SETSMS COMMDS(DFSMS.COMMDS) to start using it. //DEFCOMDS EXEC PGM=IDCAMS //SYSPRINT DD SYSOUT=* //DD1 DD UNIT=SYSDA, // VOL=SER=Z13RS2, // DISP=OLD //SYSIN DD * DELETE (DFSMS.COMMDS) CLUSTER PURGE + FILE(DD1) + CATALOG(CATALOG.MVSICFM.VZ13RS2) DEFINE CLUSTER( + NAME(DFSMS.COMMDS) + LINEAR + VOLUME(Z13RS2) + TRK(2,1) + SHAREOPTIONS(2,3) ) + DATA( + NAME(DFSMS.COMMDS.DATA)) + CATALOG(CATALOG.MVSICFM.VZ13RS2) /* Cliff McNeill ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN