It appears you are trying to restore a 3390 mod 9 to a 3390 mod 3. The 2721 you have listed below is hex for 10,017 which is the number of cylinders in a mod 9. In order to do a full volume restore your target volume will also need to be a 3390 mod 9
-----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Carlos Bodra Sent: Wednesday, May 04, 2016 1:41 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: ADR309E Message during Restore Hello I´m trying to restore a full volume backed up with ADRDSSU utility and during restore I´m getting following message: SOURCE AND TARGET DEVICE CAPACITIES DO NOT MATCH. CYLINDER CAPACITY OF SOURCE VOLUME 2721, TARGET VOLUME 0D0B. This tells me that source volume has 2721 cylinders and target volume has 3339 cylinders (0d0b). My question is how to bypass this condition checking and restore from tape source volume in a new target volume. Thanks -- CARLOS BODRA IBM Certified zSystem São Paulo - SP - BRAZIL ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN