> 2) "Continuation record" due to "record too large conditions. I.e. due multiple unconsolidated DD statements.
Yup. Thanks. > 1) STEP was "flushed" due to JCL error or COND= processing. Nope. If the job was flushed due to a JCL error no SMF record is cut. If the step was flushed due to COND= then there is a completion section. The indicator bit X'0100' is on and the completion and reason code fields are zero. Charles -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Staller, Allan Sent: Wednesday, May 18, 2016 5:39 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: What does it indicate when an SMF 30 subtype 4 or 5 has no completion section? 1) STEP was "flushed" due to JCL error or COND= processing. 2) "Continuation record" due to "record too large conditions. I.e. due multiple unconsolidated DD statements. Check the SMF manual for the gory details.. HTH, ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN