Hi Juergen, I have seen customers using uppercase unix paths. Is there a specific requirement that you cannot use uppercase paths or path parts in your shop?
Denis. -----Original Message----- From: Juergen Kehr <kehrjuer...@t-online.de> To: IBM-MAIN <IBM-MAIN@LISTSERV.UA.EDU> Sent: Thu, Jul 13, 2017 10:00 AM Subject: Question regarding system symbols Hello, in qur installation we use the system symbol &RZ for the system name. It has values like A1,B2,C3 (all letters are uppercase) Now we have to build the JCL for an STC where we would like to use this symbol, but our problem is that we need it in lowercase characters, because the value would become part of an USS path name like /abc/xyza1 or /abc/xyzb2 etc. We don't want to define new system symbols in lowercase (BTW: Is it possible to define lowercase values?), so we're looking for any good idea solving this problem. Kind regards Juergen ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to <a href="mailto:lists...@listserv.ua.edu">lists...@listserv.ua.edu</a> with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN